The Heatmiser UH8 underfloor heating wiring centre is designed to be used with 4 channels 230v time clock (TM4) and 230v Set back thermostat (DS-SB), but it can also work with any other 230v room thermostat.
The UH8 allows you to control up to 8 heating zones. It has two built-in heating time channels, and each zone can be assigned to follow a specific time channel. Additionally, there are 2 extra connections for controlling hot water or other auxiliary devices. When any zone requires heat, a 230v output is triggered to activate the corresponding for the boiler, making it compatible with most boiler types.
There is a simple slide switch that can be used to configure zone 8 for controlling a radiator zone. When used for radiators, zone 8 does not activate the underfloor heating pump, valve and boiler.
Each zone can accommodate up to 4 actuators.
The dimensions of the UH8 are 384mm (length) x 148mm (height) x 60mm (depth).